◇ Displayer: 10.4" color TFT LCD screen with maximum 7-waveform display. Adjusting of lightness continuously make patient more comfortable in midnight
◇ Battery: Rechargeable high-energy built-in battery
◇ Advanced streamline outline design, portable, compact, lightweight
◇ Operating menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, French, etc.
◇ Easy operation with user friendly menu structure design and rotary dial
◇ Against electrosurgical interference and defibrillation and no need to disconnect the monitor from the patient in process of defibrillating.
◇ WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible
◇ Optional built-in wireless networking function
◇ Support external printer to record graph and trend
◇ Intelligent audio and visual comprehensive alarm
◇ In-hospital applications include emergency pre-and post-operative care, ambulatory surgery, intermediate care/step down units, labor and delivery, and hospital-based special procedure areas.
◇ Suitable for use in physicians’ offices, clinics, outpatient surgical centers, extended care facilities and other patient care areas, which of require affordable monitoring
Standard configuration: ECG, HR, PR, SpO2, ST analysis, RESP*2 (RA-LL impedance and nasal cavity), NIBP (with venous punch), TEMP*2(surface and rectal type), Drug dose calculation.
Optional configuration: Wireless connection, Recorder and ETCO2.
Technical Parameter
|
◆Non-invasive blood pressure
|
◆Temperature
|
|
Measurement type: adult, pediatric, neonate
|
Measurement range: 25 - 45 ℃
|
|
Measurement
range:
|
Systolic
Diastolic
Mean
|
4.0 - 37.0 kPa
1.3 - 33.0 kPa
2.6 - 35.0 kPa
|
Accuracy: ± 0.1 ℃
|
|
Accuracy : ± 0.4 kPa or 5 %
|
Resolution: 0.1 ℃
|
|
Resolution: 0.1 kPa
|
Response time: ≤ 3 min.
|
|
Protection: over pressure
|
|
|
|
|
◆ECG
|
◆Respiration Rate
|
|
Input: 5 wires ECG cable
|
Measurement range: 0 - 120 BPM(adult)
|
|
Lead section: Ⅰ,Ⅱ,Ⅲ/ aVR, aVL, aVF/ V
|
Accuracy: ± 1 BPM or 5 %
|
|
Gain(mm/mV): 1/4,1/2,1,2,4
|
Resolution: 1 BPM
|
|
Frequency response:
|
Diagnosis
Monitor
Surgery
|
0.05 - 100Hz
0.5 - 40 Hz
1.0 - 25 Hz
|
◆CO2
|
|
Sweep speed (mm/sec): 12.5, 25, 50
|
Measurement range: 0 %-10.0 %
(ins CO2 and et CO2)
|
|
Heart rate range: 30-254 BPM
|
Accuracy: ± 2 mm Hg (< 5 %
Measurement value)
|
|
Heart rate accuracy: ± 1 %
|
10 % (> 5 % Measurement value)
|
|
ST segment deviation analysis: -0.8-+0.8mV
|
◆Pulse oximetry
|
|
ST accuracy: ±0.02mv
|
SPO2 measurement range: 0 - 100 %
|
|
Invasive blood pressure
|
Resolution: 1 %
|
|
Measurement range: 0~40kPa (0~300mmHg)
|
pulse measurement range: 30- 254BPM
|
|
Channel: 2 channel
|
Accuracy: ± 2 %
|
|
Transducer sensitivity: 5MV/V/mmHg
|
Resolution: 1 BPM
|
|
Unit display: kPa or mmHg selectable
|
|
|
|
◆Environment
|
|
◆Power requirements
|
|
Operation
|
Storage
|
|
Input: 98~260 V AC, 50/60Hz
|
Temperature
|
0.5 - 40 ℃
|
-20 - 50 ℃
|
|
Consumption: ≤ 80VA
|
Relative humidity
|
≤ 80%
|
≤ 90%
|
|
|
|
|
◆Safety standard: IEC 60601-1
|
|
|
Quality System: ISO13485: 2003
|
|
|